What is the scanning distance of this photoelectric sensor?
The typical maximum scanning distance of the Sick WTB11-2P2461 photoelectric sensor is between 30 and 1,100 mm.
How is the operating distance adjusted?
The operating distance of the Sick WTB11-2P2461 photoelectric sensor can be adjusted using a potentiometer.
What type of light source does this sensor use?
The Sick WTB11-2P2461 photoelectric sensor uses a Pin-Point LED, which emits red light at 660 nm.
What is the supply voltage for this sensor?
The supply voltage for the Sick WTB11-2P2461 photoelectric sensor is between 10 and 30 V DC.
What type of outputs does this sensor have?
The Sick WTB11-2P2461 photoelectric sensor has PNP, antivalent switching outputs.
What is the response time of this sensor?
The response time of the Sick WTB11-2P2461 photoelectric sensor is less than or equal to 330 μs.
What is the enclosure rating of this sensor?
The enclosure rating of the Sick WTB11-2P2461 photoelectric sensor is IP 67.
What is the operating temperature range for this sensor?
The Sick WTB11-2P2461 photoelectric sensor can operate between -30 °C and +60 °C.
What is the weight of this sensor?
The Sick WTB11-2P2461 photoelectric sensor weighs approximately 120 g.
What material is the housing of this sensor made of?
The housing of the Sick WTB11-2P2461 photoelectric sensor is made of ABS and PMMA.