What is the input voltage range for this inverter?
The input voltage range for the Siemens 6SL3210-1KE21-7AF1 inverter is 380 to 480 V, with a tolerance of +10% and -20%.
What is the output frequency range for vector control and V/f control?
For the Siemens 6SL3210-1KE21-7AF1 inverter, the output frequency range for vector control is 0 to 240 Hz, and for V/f control, it is 0 to 550 Hz.
What is the overload capability for Low Overload (LO) and High Overload (HO)?
For the Siemens 6SL3210-1KE21-7AF1 inverter, the Low Overload (LO) capability is 150% base load current IL for 3 seconds, followed by 110% base load current IL for 57 seconds in a 300-second cycle time. The High Overload (HO) capability is 200% base load current IH for 3 seconds, followed by 150% base load current IH for 57 seconds in a 300-second cycle time.
What is the cooling method used for this inverter?
The Siemens 6SL3210-1KE21-7AF1 inverter uses air cooling with an integrated fan.
What communication protocols does this inverter support?
The Siemens 6SL3210-1KE21-7AF1 inverter supports PROFINET and EtherNet/IP communication protocols.
What is the maximum motor cable length for shielded and unshielded cables?
For the Siemens 6SL3210-1KE21-7AF1 inverter, the maximum motor cable length is 50 meters (164.04 ft) for shielded cables and 100 meters (328.08 ft) for unshielded cables.
What are the dimensions and weight of this inverter?
The Siemens 6SL3210-1KE21-7AF1 inverter has dimensions of 100 mm (3.94 in) width, 196 mm (7.72 in) height, and 208 mm (8.19 in) depth. The net weight is 2.30 kg (5.07 lb).
What is the degree of protection for this inverter?
The Siemens 6SL3210-1KE21-7AF1 inverter has a degree of protection of IP20 / UL open type.